RUIJIE REYEE NIS3100-8GT2SFP-HP 8 PORT 10/100/1000 8 PORT POE 2 X SFP 240 WATT RUJIE CLOUD YONETILEBILIR ENDÜSTRİYEL SWITCH
RUIJIE REYEE NIS3100-8GT2SFP-HP
8 PORT 10/100/1000 8 PORT POE 2 X SFP 240 WATT RUJIE CLOUD YONETILEBILIR ENDÜSTRİYEL SWITCH
|
10/100/1000Base-T ports |
4 |
|
SFP ports |
2 |
|
PoE/PoE+ ports |
4 |
|
Max. PoE budget |
120W |
|
PoE Power Output |
Per port 56V DC, max 30 watts |
|
Power Pin Assignment |
1/2(+), 3/6(-) |
|
PoE Power Budget |
60W (Input: 12V-20V) 120W (Input: 21V-45V) 120W (Input: 46V-56V) |
|
Extend Mode |
250 meters |
|
Layer Type |
Layer 2 |
|
Switching capacity |
12Gbps |
|
Forwarding rate |
8.92Mpps |
|
Packet Buffer |
4.1 Mbit |
|
SDRAM |
256MB |
|
MAC address table |
8,000 |
|
Maximum VLAN Support |
4094 |
|
Dimensions (W x D x H) |
85*132*165 |
|
Weight (With package) |
1.86kg |
|
MTBF |
250,000 Hours |
|
Warranty |
5 Years |
|
Layer 2 Features |
|
|
Jumbo Frame |
9216 |
|
Flow Control |
Yes |
|
STP (IEEE 802.1d) |
Yes |
|
RSTP (IEEE 802.1w) |
Yes |
|
Port Fast |
Yes |
|
BPDU Guard |
Yes |
|
Errdisable Recovery |
Yes |
|
Link Aggregation |
Yes |
|
Max. Aggregation Group |
8 |
|
Max. Member per Group |
8 |
|
Unknow Unicast Storm Suppression |
Yes |
|
Multicast / Broadcast Storm Suppression |
Yes |
|
Many-to-One Mirroring |
Yes |
|
VLAN Range |
1-94 |
|
Port-based VLAN |
Yes |
|
Voice VLAN |
Yes |
|
RLDP |
Yes |
|
LLDP / LLDP-MED |
Yes |
|
Cable Testing |
Yes |
|
IGMP Snooping v1/v2/v3 |
Yes |
|
Software Features |
|
|
ERPS* |
Yes |
|
Ping |
Yes |
|
Traceroute |
Yes |
|
ACL Entries |
1200 |
|
IP Standard ACL |
Yes |
|
MAC-based Extended ACL |
Yes |
|
IP-based Extended ACL |
Yes |
|
Port-based Rate Limit (Ingress/Egress) |
Yes |
|
SNMP v1/v2c/v3 |
Yes |
|
Web Management |
Yes |
|
Management IP |
10.44.77.200 |
|
HTTP/HTTPS |
Yes |
|
Cloud Management |
Yes |
|
APP Management |
Yes |
|
SON (Self-Organizing Network) with IP |
Yes |
|
Camera Recognition |
Yes |
|
Loop Prevention |
Yes |
|
Loop Notification |
Yes |
|
PoE Usage Alarm |
Yes |
|
Protection Port |
Yes |
|
IP Source Guard |
Yes |
|
Anti-ARP Spoofing |
Yes |
|
DHCP Snooping |
Yes |
|
DHCP Client |
Yes |
|
AAA |
Yes |
|
802.1x |
Yes |
|
watchdog |
Yes |
|
DDM (Digital diagnostics monitoring) |
Yes |
|
Physical Features |
|
|
Flash Memory |
16MB |
|
Reset Button |
<2 sec: System reboot >5 sec: Factory default |
|
Cable Hot-swappable |
Yes |
|
Power Requirements |
Dual 12-56V DC |
|
Power Supplies |
Rated voltage range: 12-56V Rated current:7A |
|
Power Consumption |
No PoE load: 12W PoE load: 72W (Input: 12V-20V) 132W (Input: 21V-56V) |
|
EEE |
Yes |
|
Fan |
Fanless design |
|
Acoustic Noise |
<30dB (when the device works normally) |
|
Operating Temperature |
-40°C to +80°C (when installed in a fume hood with a blower, with the face velocity no less than 400 LFM) -40°C to +75°C (when installed in a fume hood with a blower, with the face velocity no less than 200 LFM) -40°C to +70°C (when installed in a fume hood with a blower, with the face velocity no less than 80 LFM) -40°C to +65°C (when installed in an enclosed space) |
|
Storage Temperature |
-40~75℃ |
|
Operating Humidity |
5% to 95% RH |
|
Storage Humidity |
5% to 95% RH |
|
Lighting/Surge immunity (Surge) |
IEC61000-4-5, Class 5 6kV |
|
Electrostatic Discharge (ESD) |
IEC61000-4-2, Level 3 Air Discharge: 8KV Contact Discharge: 6KV |
|
Enclosure |
IP40 aluminium casing |
|
Anti-corrosion |
Conformal Coating |
|
Installation |
DIN-rail Mounting Wall-mount |
|
Connector |
Pin 1/2Removable 6-pin terminal block for power input for Power 1,Pin 3/4 for fault alarm, Pin 5/6 for Power 2 |
|
Alarm |
One relay output for power failure. Alarm relay current carry ability : 1A@30V DC, |
|
LED Indicator |
System: Power 1(Green) Power 2(Green) SYS(Green) Per RJ45 POE+ Ports: PoE-in-Use(Orange) LINK/ACT(Green) Per SFP Interface: LINK/ACT(Green) |
|
Operating Altitude (meters) |
-500 to 2000m |
|
Certificate |
CE, RoHS |
|
EMC |
IEC/EN 61000-4-2 IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, Level3 IEC/EN 61000-4-3 IEC 61000-4-3 RS:10V Level3 IEC/EN 61000-4-4 IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV, Level3 IEC/EN 61000-4-5 IEC 61000-4-5 Surge: Power: 4 kV(with industrial power supply module); Signal: 6 kV, Level 4 IEC/EN 61000-4-6 IEC 61000-4-6 CS:10V Level3 IEC/EN 61000-4-8 IEC 61000-4-8 10A/m Level3 |